GMP Cleanroom Constant Temperature Humidity Air Treatment Unit

Shanghai Shenglin M&E Technology Co., Ltd.
Contact Now

GMP Cleanroom Constant Temperature Humidity Air Treatment Unit

  • 1
  • 2

Brand Name : Shenglin

Model Number : Not standard

Certification : CE

Place of Origin : China

MOQ : 1

Price : 3200~29000USD/unit

Payment Terms : T/T, Western Union

Supply Ability : 50~100 units/ month

Delivery Time : 40~45days

Packaging Details : Stretch film+ pallet for container loading, plywood box for less container loading.

Type : Constant temperature and humidity type

Compressor type : Inverter compressor

Heat exchanger type : Inner grooved copper tube and hydrophilic aluminum fin

Operating voltage : 3N-380V-50 or 60Hz

Refrigerant : R22, R410A or R407C

Warranty : 1 year

Supply fan : EC fan

Air Filter : Primary effect plate filter, Middle effect bag filter and

Keyword : Temperature and humidity direct expansion unit

Contact Now

Clean Room Constant Temperature And Humidity Air Handling Units

Product series which we can do:

1. Constant temperature and humidity type unit
2. Clean room constant temperature and humidity unit
3. Heating and cooling heat pump type unit (including fresh air type)
4. Heating and cooling type unit (including fresh air type)
5. Single cooling unit (including fresh air type)
6. Multifunctional unit
7. Double cold source deep dehumidification unit
8. Double cold source fast cooling air conditioning unit

Feature:

1. Filter: G4+F7+F11+FFU(end user side).

2. 10~30% fresh air.

3. Inveter compressor.

4. EC fans.

5. Analog control valve.

6. Dry coils

7. Meet GMP requirements

8. Purification engineering: including electronic information, semiconductors, optoelectronics, precision manufacturing, medicine and health, biological engineering, aerospace, automotive spraying and many other industries

Advantage of direct expansion air handling units:

No water system, no secondary heat exchange, no large computer room and control, simple installation and construction

The difference with other air conditioning units:

1. Good sealing, heat preservation and pressure bearing performance (low air leakage rate, low deformation rate, no cold bridge);
2. Avoid secondary pollution (dry water tray, hydrophilic membrane surface cooler, no belt dust, no bacteria breeding)
3. Adjustable air volume (fan motor frequency conversion);
4. High filtration level (primary, middle and sub-high efficiency);
5. Complex functional sections (filtration, cooling, heating, dehumidification, humidification, noise reduction, disinfection);
6. The front wind speed should not be too high;
7. Centralized control is required (reserved information panel interface).

Parts and material:

1. Frame and panel:

A. Adopt double-sided incubator panels, all outer panels are made of color galvanized steel, and the inner panel can be equipped with color galvanized steel or stainless steel according to user needs;
B. The thermal insulation layer is directly foamed with rigid polyurethane (PU) with a thickness of 50mm;
C.The box board adopts patented anti-cold bridge technology.

2. Heat Exchanger:

A. The standard configuration is copper tube with aluminum fin with anticorrosive hydrophilic coating

B. The collection tube is all made of red copper tube, and the welding quality of the same material is guaranteed;

C. The expansion tube adopts a mechanical low-speed pulsation process, which has high heat transfer efficiency;

D. Pipe pressure test and leak detection one by one, the maximum working pressure can reach 25bar;

E. Equipped with stainless steel dry condensate pan;

F. If necessary, the machine can be equipped with antifreeze protection device for coil maintenance during shutdown

3. Electric heating:

A. Adopt thermal ceramic electric heating element; no short circuit problem, which helps to eliminate fire hazards;

B. No electricity on the surface, no electric shock hazard;

C. Heating element has no oxidation problem and has a long service life;

D. Each PTC is equipped with a high temperature protection switch;

E. Can offer duct type PTC electric heating box

4. Electrode humidifier:

A. Adopt Swiss condair electrode humidifier;

B. Integrated structure, beautiful appearance, more convenient for maintenance outside the cabinet;

C. Replaceable or washable humidification barrel, maintenance-free electrode;

D. Equipped with stainless steel humidification nozzle and connecting hose;

E. Equipped with water quality adjustment It can adapt to the humidification needs under various water quality conditions;

F. It can be controlled by the unit controller to achieve continuous control of the humidification amount;

G. Or it can be equipped with a humidification controller for independent humidity control;

H. Other brand products can be optional


Product Tags:

GMP air treatment unit

      

Cleanroom air treatment unit

      

Cleanroom ac handler unit

      
Best GMP Cleanroom Constant Temperature Humidity Air Treatment Unit wholesale

GMP Cleanroom Constant Temperature Humidity Air Treatment Unit Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shanghai Shenglin M&E Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)